ASHRAE TC 9.9 recommended inlet air temperature ranges for most IT equipment are:
Correct: (a) Defined environmental classes allowing wider bands than legacy 20–25°C-only designs. TC 9.9 classes support higher supply temps where equipment allows, improving economizer hours.

A CRAH (Computer Room Air Handler) differs from a CRAC primarily because:
Correct: (a) CRAH uses chilled water coils while CRAC typically has integral refrigeration. CRAHs are air handlers connected to central chiller plants; CRACs are self-contained DX units.

Chilled water supply temperature elevation (within ASHRAE limits) can:
Correct: (a) Improve chiller efficiency and increase free cooling hours. Higher CHW temps raise evaporator temperature and reduce chiller lift.
Ready to drill with the full deck?
Instant .apkg download after Gumroad checkout.
Get 250-Card CDCP Deck — $11 USDPairs with
ASHRAE Certs
Anki deck for BCxP, BEMP, BEAP, CHD, HBDP, HFDP, and OPMP exam prep.
Product facts
- Cards
- 250+
- Coverage
- Facilities (power, cooling, fire, security) and Operations per EXIN EPI CDCP blueprint
- Format
- .apkg
- Price
- $11 USD
- Checkout
- Gumroad
- Exam cycle
- Current EXIN EPI CDCP cycle
- Delivery
- Digital .apkg through Gumroad (instant download)
Coverage by exam topic
| Topic | Exam weight | Cards |
|---|---|---|
| Site, Standards, and Building | ~7.5% | 50 |
| Power Infrastructure and EMF | ~20% | 50 |
| Cooling, Water, and Thermal | ~12.5% | 50 |
| Fire Protection, Security, and Network | ~35% | 50 |
| Data Centre Operations | 15% | 50 |
Exam facts
EXIN EPI Certified Data Centre Professional (CDCP)
The EXIN EPI Certified Data Centre Professional (CDCP) credential validates foundational knowledge of data centre facility infrastructure and operations. Accredited training through an EPI authorized partner is required before sitting the exam. UniPrep2Go products are independent prep (not EXIN or EPI exam material).
- Questions
- 40 multiple-choice
- Time
- 60 minutes
- Passing score
- 68% (27 of 40 correct)
- Delivery
- Computer-based or paper-based at end of accredited EPI CDCP training course (verify delivery route with your training partner)
- Administered by
- EXIN (accredited by EPI — Enterprise Products Integration)
Knowledge domains and weights
| Domain | Weight |
|---|---|
| Facilities — Mission Critical Site, Standards, Location & Building | ~7.5% (3 of 40 questions) |
| Facilities — Raised Floor, Lighting, Racks, and Network Infrastructure | ~17.5% (7 of 40) |
| Facilities — Power Infrastructure | 15% (6 of 40) |
| Facilities — Electro Magnetic Fields (EMF) | 5% (2 of 40) |
| Facilities — Cooling Infrastructure | 10% (4 of 40) |
| Facilities — Water Supply | 2.5% (1 of 40) |
| Facilities — Fire Protection | 15% (6 of 40) |
| Facilities — Physical Security, Safety, and Auxiliary Systems | 12.5% (5 of 40) |
| Operations — Operational Considerations | 15% (6 of 40) |
What changed in the current exam cycle
- CDCP is part of the EXIN EPI Data Centre Training Framework — CDCS (specialist) and CDCE (expert) are higher tiers on the same pathway.
- Certificate validity is 3 years — recertification through EPI's recertification programme (verify current options at epi-ap.com).
- EXIN lists training as mandatory — candidates typically sit the exam immediately after the 2-day accredited CDCP course.
- An electronic dictionary is permitted during the exam; other electronic aids and open-book references are not.
High-yield facts (commonly tested)
- Pass mark is 27 of 40 (68%) — closed book, 60 minutes.
- Facilities of the Data Centre accounts for ~85% of exam questions (34 of 40); Operations ~15% (6 of 40).
- Power Infrastructure (6 questions) and Fire Protection (6 questions) are the highest-weight subtopics on the facilities side.
- Standards referenced include TIA-942, Uptime Institute Tier classification, EN 50600 / ISO 22237, and ASHRAE TC 9.9 thermal guidelines.
- Hot aisle / cold aisle containment, free cooling, and CRAC/CRAH topologies are core cooling concepts.
- PUE (Power Usage Effectiveness) is the primary data centre energy efficiency metric.
- NFPA 75/76 and clean-agent suppression systems are common fire-protection knowledge areas.
Common EXIN EPI Certified Data Centre Professional (CDCP) questions
Straight answers to the questions candidates usually search before buying prep or booking the exam.
How many questions are on the CDCP exam?
40 multiple-choice questions in 60 minutes — all 40 are scored.
What score do you need to pass the CDCP exam?
68% — at least 27 correct answers out of 40.
Is the CDCP exam open book?
No. The exam is closed book. EXIN permits an (electronic) dictionary only.
Do I need training before the CDCP exam?
Yes. EXIN lists accredited EPI training as mandatory. The exam is typically taken at the end of the 2-day CDCP course.
How long is the CDCP certificate valid?
3 years. Recertify through EPI's recertification programme or progress to CDCS/CDCE credentials.
Verify current exam fees, scheduling, and administrative details at www.exin.com/technologies-software/exin-epi-data-centre-management/certified-data-centre-professional. Independent study aid — not official exam material.
More about CDCPStudy tips, positioning, and how this deck compares
CDCP exam prep
UniPrep2Go sells an independent CDCP Anki deck with 250+ high-yield flashcards for active recall and exam terminology. Built from the same validated item bank as the free readiness check at https://uniprep2go.study/mock-exams/cdcp-readiness-check. It is delivered as an Anki .apkg file for $11 USD through Gumroad with i
Built for: Data centre operators, facility engineers, and IT infrastructure professionals preparing for the EXIN EPI CDCP credential after accredited EPI training.
Covers: Facilities (power, cooling, fire, security) and Operations per EXIN EPI CDCP blueprint.
- Spaced-repetition flashcards
- 250+ exam-focused flashcards
- Topic coverage table and samples on this page
- Linked free 40-question practice test
How this deck compares
250+ cards for CDCP matches the current facilities (power, cooling, fire, security) and operations per exin epi cdcp blueprint in the coverage table — sized for daily review, not maximum download size. Start with the free 40-question CDCP practice test, then drill weak rows from the table.
| Approach | Typical size | Tradeoffs |
|---|---|---|
| Free community decks | 1,000–3,000 |
|
| Budget mega-packs | 1,000+ |
|
| This deck | 250+ exam-focused flashcards |
|
CDCP study guide
What is inside
250 MCQ cards across the EXIN EPI CDCP facility and operations blueprint: site/standards/building, power & EMF, cooling/water/thermal, fire/security/network, and data-centre operations. Every card has a correct explanation plus short notes on why the other three options fail — the same bank that feeds the free timed readiness check.
3–4 week study plan with the free mock
**Week 1:** 20 new cards/day across power and cooling while you finish EPI course registration. **Week 2:** Keep 15–20 new cards/day and add fire/security. **Week 3:** Sit the [free 40-question CDCP readiness check](/mock-exams/cdcp-readiness-check) (60 minutes, 68% target). **Final days:** Review-only Anki on weak topics from the report — do not dump new cards the night before the accredited-course exam sitting.
Pitfalls this deck targets
Candidates confuse CRAH vs CRAC, mix UPS topology tiers with marketing “N+1” claims, and forget that high RH causes condensation while low RH raises ESD risk. Cards force the facility distinction under timed recall, not brochure definitions.
What this does not replace
Accredited EPI CDCP training is mandatory on the official exam path. This deck is independent spaced-repetition drill — not EXIN or EPI exam material.
EXIN EPI Certified Data Centre Professional (CDCP) & product FAQ
How many questions are on the CDCP exam?
40 multiple-choice questions in 60 minutes — all 40 are scored.
What score do you need to pass the CDCP exam?
68% — at least 27 correct answers out of 40.
Is the CDCP exam open book?
No. The exam is closed book. EXIN permits an (electronic) dictionary only.
Do I need training before the CDCP exam?
Yes. EXIN lists accredited EPI training as mandatory. The exam is typically taken at the end of the 2-day CDCP course.
How long is the CDCP certificate valid?
3 years. Recertify through EPI's recertification programme or progress to CDCS/CDCE credentials.
Is there a free CDCP practice test?
Yes. Take the linked readiness check at https://uniprep2go.study/mock-exams/cdcp-readiness-check before you buy — topic scoring shows what to drill in the deck.
More questions (2)
Does this replace EXIN or EPI official training?
No. Accredited EPI CDCP training is mandatory before the official exam. This deck and mock are supplementary independent prep.
Is this official EXIN or EPI material?
No. Independent study aid — not affiliated with or endorsed by EXIN or EPI.
Also useful
Guides for CDCP
State rules, test-day logistics, and study plans that point back to this practice path.
Last updated 2026-08-06.